Skip to main content
Menu
US

NEXTFLEX RiboNaut rRNA Depletion Kit (Human / Mouse / Rat)

The NEXTFLEX® RiboNaut rRNA depletion kit (human / mouse / rat) is an effective method to remove rRNA contamination from mammalian total RNA while enabling labs to interrogate additional RNA species in a sample, not only limited to intact mRNAs.

For research use only. Not for use in diagnostic procedures. 

Product Variants
Part number: NOVA-512961
Format: Manual
Unit Size: 8 rxns 
List price: USD 424.84
Your price:
USD 0.00
USD 424.84 /each
Part number: NOVA-512962
Format: Manual
Unit Size: 48 rxns 
List price: USD 2,545.00
Your price:
USD 2,545.00
USD 2,545.00 /each
Part number: NOVA-512964
Format: Automated
Unit Size: 48 rxns
List price: USD 2,472.00
Your price:
USD 0.00
USD 2,472.00 /each
Part number: NOVA-512963
Format: Manual
Unit Size: 96 rxns 
List price: USD 5,090.00
Your price:
USD 0.00
USD 5,090.00 /each
Part number: NOVA-512965
Format: Automated
Unit Size: 96 rxns
List price: USD 5,090.00
Your price:
USD 0.00
USD 5,090.00 /each
Do you need Unique Dual Index Barcodes?
Revvity
Part number: NOVA-512920
List price: USD 1,019.00
Your price: Login to view
USD 0.00
USD 1,019.00 /each
Revvity
Part number: NOVA-512920-EVAL48
List price: USD 253.86
Your price: Login to view
USD 0.00
USD 253.86 /each
Do you need a RNA-seq library prep kit?
Revvity
Part number: NOVA-5198-02
List price: USD 2,228.00
Your price: Login to view
USD 0.00
USD 2,228.00 /each

Overview

  • Hybridization and bead-based protocol for rRNA depletion
  • Optimized for use with 5 ng – 1 µg of total RNA as starting material
  • Tested using the NEXTFLEX® Rapid Directional RNA-Seq Kit 2.0 and automated on the Sciclone® G3 NGSx and Zephyr® G3 NGS workstations
  • Versions are available for automated and manual rRNA depletion

The NEXTFLEX RiboNaut Kit Ensures Effective rRNA Depletion using Hybridization Technology

The NEXTFLEX RiboNaut rRNA depletion kit (human / mouse / rat) utilizes subtractive hybridization technology consisting of a mixture of biotinylated oligos complementary to rRNAs to pull them out of the sample using streptavidin-coated magnetic beads. The kit has been optimized for use with 5 ng – 1 µg of total RNA as starting material to deplete cytoplasmic and mitochondrial rRNAs. It has been verified to be compatible with human, mouse, and rat RNA and it may be compatible with other mammalian species.

Additional product information

nextflex ribonaut rRNA depletion kit fig-1

Figure 1: Example of 1 µg of Universal Human Reference RNA (Agilent® #740000) after rRNA depletion. 1 µL of rRNA-depleted RNA was run on the LabChip GXII Touch HT Nucleic Acid Analyzer using the RNA Pico Assay Reagent Kit (# CLS960012) and a DNA/RNA/Charge Variant Assay (# 760435).

Optimized to Produce Robust Performance Data from Total RNA Samples

The NEXTFLEX RiboNaut rRNA Depletion kit (human / mouse / rat) shows robust performance data using total RNA samples for gene coverage along a transcript, duplication rate, directionality, and rRNA contamination. Prior to rRNA depletion and subsequent RNA-seq, qualification of total RNA integrity using the LabChip GXII Touch HT Nucleic Acid Analyzer.

As an alternative mRNA-Seq solution for intact poly(A)-tailed mRNA species, Revvity offers the NEXTFLEX Poly(A) Beads 2.0 for use NEXTFLEX Rapid Directional RNA-Seq kit 2.0 or other applications.

Robust Gene Coverage
nextflex ribonaut rRNA depletion kit fig-2

Figure 2. The NEXTFLEX Rapid Directional RNA-Seq kit 2.0 demonstrates even coverage along transcripts compared to the Competitor N kit. rRNA-depleted total RNA was isolated from Universal Human Reference RNA (Agilent #740000) using the NEXTFLEX RiboNaut rRNA depletion kit (human, mouse, rat) and the Competitor N rRNA-depletion kit. Libraries were generated using the NEXTFLEX Rapid Directional RNA-Seq kit 2.0 and the Competitor N’s library preparation kit. The resulting libraries were sequenced on the Illumina®  MiSeq® sequencer using single-end mode (1×151 bp). Reads were trimmed using cutadapt, mapped to the Gencode v30 reference transcriptome using bowtie2, and randomly downsampled to 720k reads. The coverage along transcripts was calculated using the BBMap pileup tool.

Low Duplication Rate
nextflex ribonaut rRNA depletion kit fig-3

Figure 3. The NEXTFLEX Rapid Directional RNA-Seq kit 2.0 demonstrate low duplication rates compared to the Competitor N kit. rRNA-depleted total RNA was isolated from Universal Human Reference RNA (Agilent  #740000) using the NEXTFLEX  RiboNaut rRNA depletion kit (human, mouse, rat) and the Competitor N rRNA-depletion kit. Libraries were generated using the NEXTFLEX Rapid Directional RNA-Seq kit 2.0 and the Competitor N’s library preparation kit. The resulting libraries were sequenced on the Illumina MiSeq sequencer using single-end mode (1×151 bp). Reads were trimmed using cutadapt, mapped to the Gencode v30 reference transcriptome using bowtie2, and randomly downsampled to 28k reads. Duplication rate was calculated using the fastp all-in-one FASTQ preprocessor.

Reliable Directionality
nextflex ribonaut rRNA depletion kit fig-4

Figure 4. The NEXTFLEX Rapid Directional RNA-Seq kit 2.0 demonstrates comparable directionality relative to the Competitor N kit. rRNA-depleted total RNA was isolated from Universal Human Reference RNA (Agilent #740000) using the NEXTFLEX RiboNaut rRNA depletion kit (human, mouse, rat) and the Competitor N rRNA-depletion kit. Libraries were generated using the NEXTFLEX Rapid Directional RNA-Seq kit 2.0 and the Competitor N’s library preparation kit. The resulting libraries were sequenced on the Illumina MiSeq sequencer using single-end mode (1×151 bp). Reads were trimmed using cutadapt and mapped to the Gencode v30 reference transcriptome using bowtie2. Reads from respective samples were combined and downsampled for a total of 800k reads each. Strandedness was calculated using the fastp all-in-one FASTQ preprocessor.

Low Levels of rRNA Contamination
nextflex ribonaut rRNA depletion kit fig-5

Figure 5. The NEXTFLEX Rapid Directional RNA-Seq kit 2.0 delivers libraries containing low levels of rRNA contamination compared to the Competitor N kit. rRNA-depleted total RNA was isolated from Universal Human Reference RNA (Agilent #740000) using the NEXTFLEX RiboNaut rRNA depletion kit (human, mouse, rat) and the Competitor N rRNA-depletion kit. Libraries were generated using the NEXTFLEX Rapid Directional RNA-Seq kit 2.0 and the Competitor N’s library preparation kit. The resulting libraries were sequenced on the Illumina MiSeq sequencer using single-end mode (1×151 bp). The reads were trimmed using cutadapt and the percent of rRNA was determined by using bowtie2 to map reads to human rRNA. The NEXTFLEX Rapid Directional RNA-Seq kit 2.0 demonstrated superior removal of 5S, 5.8S, 12S, 16S, 18S, and 28S rRNA species compared to the Competitor N kit.

Automated vs. Manual Prep
nextflex ribonaut rRNA depletion kit fig-6

Figure 6. Libraries prepared using the Sciclone G3 NGSx workstation and manually deliver comparable yields using the NEXTFLEX Rapid Directional RNA-Seq kit 2.0. rRNA-depleted total RNA was isolated from Universal Human Reference RNA (Agilent #740000) using the NEXTFLEX RiboNaut rRNA depletion kit. Libraries were generated using the NEXTFLEX Rapid Directional RNA-Seq kit 2.0. Final library concentrations were quantified using the Qubit ® 2.0 fluorometer (Thermo Fisher® Scientific #Q32866).

Specifications

Brand
NEXTFLEX
Format
Manual
Type
RNA-seq
Unit Size
48 rxns 
SDS, COAs, Manuals and more Illuminator

SDS, COAs, Manuals and more

Are you looking for technical documents for this product. We have housed them in a dedicated section., click on the links below to explore.

5 of 26 selected

CRISPR-based Ribodepletion

Jumpcode-box-image_700x700
Part number: NOVA-512860
List price: USD 6,000.00
Your price: Login to view
USD 0.00
USD 6,000.00 /each
Jumpcode-box-image_700x700
Part number: NOVA-512870
List price: USD 1,200.00
Your price: Login to view
USD 0.00
USD 1,200.00 /each
Jumpcode-box-image_700x700
Part number: NOVA-512890
List price: USD 1,200.00
Your price: Login to view
USD 0.00
USD 1,200.00 /each
Jumpcode-box-image_700x700
Part number: NOVA-5229910
List price: USD 7,680.00
Your price: Login to view
USD 0.00
USD 7,680.00 /each
Jumpcode-box-image_700x700
Part number: NOVA-5229920
List price: USD 7,680.00
Your price: Login to view
USD 0.00
USD 7,680.00 /each
Jumpcode-box-image_700x700
Part number: NOVA-5229950
List price: USD 2,160.00
Your price: Login to view
USD 0.00
USD 2,160.00 /each
Jumpcode-box-image_700x700
Part number: NOVA-5229960
List price: USD 3,777.00
Your price: Login to view
USD 0.00
USD 3,777.00 /each

Adapters

Revvity
Part number: NOVA-512920
List price: USD 1,019.00
Your price: Login to view
USD 0.00
USD 1,019.00 /each
Revvity
Part number: NOVA-512920-EVAL16
List price: USD 84.97
Your price: Login to view
USD 0.00
USD 84.97 /each
Revvity
Part number: NOVA-512920-EVAL48
List price: USD 253.86
Your price: Login to view
USD 0.00
USD 253.86 /each
Revvity
Part number: NOVA-512921
List price: USD 1,019.00
Your price: Login to view
USD 0.00
USD 1,019.00 /each
Revvity
Part number: NOVA-512922
List price: USD 1,019.00
Your price: Login to view
USD 0.00
USD 1,019.00 /each
Revvity
Part number: NOVA-512923
List price: USD 1,019.00
Your price: Login to view
USD 0.00
USD 1,019.00 /each

Poly(A) Depletion

Revvity
Part number: NOVA-512991
List price: USD 47.21
Your price: Login to view
USD 0.00
USD 47.21 /each
Revvity
Part number: NOVA-512992
List price: USD 207.70
Your price: Login to view
USD 0.00
USD 207.70 /each
Revvity
Part number: NOVA-512993
List price: USD 395.47
Your price: Login to view
USD 0.00
USD 395.47 /each
Revvity
Part number: NOVA-512994
List price: USD 200.36
Your price: Login to view
USD 0.00
USD 200.36 /each
Revvity
Part number: NOVA-512995
List price: USD 395.47
Your price: Login to view
USD 0.00
USD 395.47 /each

RNA-Seq Library Prep

Revvity
Part number: NOVA-5198-01
List price: USD 370.30
Your price: Login to view
USD 0.00
USD 370.30 /each
Revvity
Part number: NOVA-5198-02
List price: USD 2,228.00
Your price: Login to view
USD 0.00
USD 2,228.00 /each
Revvity
Part number: NOVA-5198-03
List price: USD 4,455.00
Your price: Login to view
USD 0.00
USD 4,455.00 /each
Revvity
Part number: NOVA-5198-43
List price: USD 2,162.00
Your price: Login to view
USD 0.00
USD 2,162.00 /each
Revvity
Part number: NOVA-5198-53
List price: USD 4,455.00
Your price: Login to view
USD 0.00
USD 4,455.00 /each
5 of 26 selected
Scroll Icon