Skip to main content
Menu
US

NEXTFLEX Poly(A) Beads 2.0

The NEXTFLEX® Poly(A) Beads 2.0 kit offers a convenient method for the purification of pure, intact mRNA upstream of RNA-Seq library prep with improved mRNA yields, low rRNA contamination, and a simple protocol.

For research use only. Not for use in diagnostic procedures.

Feature Specification
Automation Compatible Yes
Product Group mRNA Enrichment

The NEXTFLEX® Poly(A) Beads 2.0 kit offers a convenient method for the purification of pure, intact mRNA upstream of RNA-Seq library prep with improved mRNA yields, low rRNA contamination, and a simple protocol.

For research use only. Not for use in diagnostic procedures.

Product Variants
Unit Size: 8 rxns
Format
Manual
Part #:
NOVA-512991
List Price
USD 47.21
Unit Size: 48 rxns
Format
Manual
Part #:
NOVA-512992
List Price
USD 207.70
Unit Size: 48 rxns
Format
Automation Friendly Volumes
Part #:
NOVA-512994
List Price
USD 224.00
Unit Size: 96 rxns
Format
Manual
Part #:
NOVA-512993
List Price
USD 395.47
Unit Size: 96 rxns
Format
Automation Friendly Volumes
Part #:
NOVA-512995
List Price
USD 443.00

Overview

  • 10 ng – 5 µg total starting RNA
  • Magnetic bead-based protocol
  • No organic solvents or precipitation step required
  • Optimized for use with 10 ng – 5 µg of total RNA as starting material
  • Versions are available for automated and manual isolation of the mRNA transcriptome
  • Automated on the Sciclone® G3 NGSx and Zephyr® G3 NGS workstations

Poly(A)-tailed mRNA is isolated via magnetic beads conjugated to oligo(dT), and separation using a magnetic stand allows for high mRNA recovery. The intact mRNA is eluted in small volumes, thereby eliminating the need for precipitation. These beads have been tested with the NEXTFLEX® Rapid Directional RNA-Seq Kit 2.0.

Additional product information

Reducing Ribosomal rRNA Reads in RNA-seq Libraries 

Several approaches have been used to remove ribosomal RNA (rRNA) from total RNA samples for RNA-Seq library preparation. Removal of rRNA avoids the waste of reagents and bioinformatics resources to sequence and align ~85% of total RNA comprising rRNA (which is generally not a target of interest in NGS sequencing experiments). Revvity’s NEXTFLEX Poly(A) beads 2.0 kit offers an easy and cost-effective method for removing rRNA in RNA-Seq libraries. This product takes advantage of the tract of adenosine residues present at the 3’ ends of a vast majority of protein-coding mRNAs. Hybridization of these poly(A) tails to tracts of complementary thymidines (“oligo dT”) immobilized on solid supports allows the retrieval of poly(A)+ RNAs by recovering the solid support along with the hybridized RNA complexes.

nextflex poly a beads 2.0 fig1

Figure 1. Example of 1 µg of Universal Human Reference RNA (Agilent® # 740000) after mRNA enrichment using the NEXTFLEX Poly(A) Beads 2.0.  3 µL Poly(A) enriched RNA was run on the LabChip® GX Touch HT Nucleic Acid Analyzer using the RNA Pico Assay Reagent Kit (# CLS960012) and a DNA/RNA/Charge Variant Assay LabChip (# 760435)

nextflex poly a beads 2.0 fig 2

(A) mouse brain

nextflex poly a beads 2.0 fig3

(B) MCF7 cells

Figure 2. NEXTFLEX Poly(A) Beads 2.0 yield clean mRNA with minimal rRNA carry-over from 5 µg of total RNA input from (A) mouse brain and (B) MCF7 cells. ~1.5% rRNA carry-over was observed based on sequencing data.

For total RNA-Seq solution not limited to only mRNA-Seq, Revvity offers the NEXTFLEX RiboNaut rRNA depletion kit (Human / Mouse / Rat) for use NEXTFLEX Rapid Directional RNA-Seq Kit 2.0 or other applications.

Specifications

Automation Compatible
Yes
Format
Automation Friendly Volumes
Product Group
mRNA Enrichment
Shipping Conditions
Shipped Ambient
Unit Size
48 rxns

Resources

Are you looking for resources, click on the resource type to explore further.

1-1 of 1 Resources
Flyer Icon
Flyer
New and improved library preparation kit for your RNA sequencing needs

This flyer describes the benefits of the NEXTFLEX® Rapid Directional RNA-seq 2.0 Kit.

Scroll Icon