The GSP® is a high throughput batch analyzer intended for quantitative or qualitative measurement of neonatal screening samples.
Product may not be available in all countries. Confirm availability with your local Revvity representative.
The instrument is fully automated, performing every stage of an assay from retrieval of the sample plate from the stacker to measurement and reporting of results. Genetic Screening Processor utilizes specific GSP Workstation software for handling of the newborn screening data.
Design of GSP Instrument, software and screening assays offers multiple advantages for your screening program, including:
The automated high throughput platform for screening disorders in newborns using both DELFIA immunoassay and enzymatic technologies. The GSP newborn screening system offers outstanding accuracy and reliability, coupled with high efficiency and user-friendliness. It brings the future of neonatal screening to your laboratory, helping you provide children with a healthier start to life.
Using dried blood spot samples (DBS) the GSP platform reduced hands-on stages and reduced risk of error through automation from plate loading to results output.
Prepare the worklist
This can be generated automatically by the Puncher or added manually using the workstation software
Load reagents
Barcoded reagents are loaded to the cooled reagent carousel in the GSP instrument.
Load and run samples
The touch screen allows you to prioritize the running order of your plates as you wish and see instantly the status of your assays, consumables, reagents and waste capacity.
Analyse results
Results are automatically delivered to you at the GSP Workstation computer. You can check the calibration curve, quality control levels, possible notifications about the run, accept the assay and export and print results.
Saving you time and effort while reducing risk of errors
GSP Neonatal kits are the industry standard for analytical performance and reliability. Each kit includes reagents, QC material and specific QC certificates. Barcoding reduces the risk of errors, and all calibrators and controls come in dried blood spot format. The cooled reagent compartment also eliminates the need to unload reagents after assay runs and improves screening accuracy.
The GSP instrument is optimized for continuous sample loading. The loaded plates are processed automatically or users can prioritize the order in which plates are processed.
Newborn screening software that provides control and monitoring tools for the entire screening process.
Specimen Gate software is designed to simplify the data collection and workflow processes
involved with receiving specimens, screening for abnormalities, managing patient information, generating specimen reports, and following up abnormal and unsatisfactory specimens.
Application |
Newborn Screening
|
---|---|
Brand |
GSP®
|
Detection Modality |
DELFIA
Enzymatic
|
Disorders |
Biotinidase (BTD) Deficiency
Congenital Adrenal Hyperplasia (CAH)
Congenital Hypothyroidism
Cystic Fibrosis
Galactosemia
Glucose-6-phosphate Dehydrogenase (G6PD) Deficiency
Phenylketonuria
|
Unit Size |