Skip to main content
Menu
US

HTRF Human & Mouse TOM20 Detection Kit, 500 Assay Points

The HTRF TOM20 kit is designed for the simple and rapid quantification of the protein in cell-based formats.

For research use only. Not for use in diagnostic procedures. All products to be used in accordance with applicable laws and regulations including without limitation, consumption and disposal requirements under European REACH regulations (EC 1907/2006).

Feature Specification
Application Protein Quantification
Sample Volume 16 µL

The HTRF TOM20 kit is designed for the simple and rapid quantification of the protein in cell-based formats.

For research use only. Not for use in diagnostic procedures. All products to be used in accordance with applicable laws and regulations including without limitation, consumption and disposal requirements under European REACH regulations (EC 1907/2006).

Product Variants
Unit Size: 500 Assay Points
Part #:
64TOM20PEG
List Price
USD 1,429.62
Unit Size: 10,000 Assay Points
Part #:
64TOM20PEH
List Price
USD 14,590.00

Overview

The removal of damaged mitochondria is critical for maintaining cellular homeostasis. The Translocase of Outer Membrane (TOM) receptor complex is responsible for the movement of proteins through the outer mitochondrial membrane of the mitochondria into the intermembrane space. TOM20 is a central component of the TOM complex. Monitoring the degradation of TOM20 is an indicator of mitophagy activation. This kit is intended to measure TOM20 in cellular lysates. The assay is a fast alternative to ELISA, thanks to the easy implementation of our Add and Read method.

Specifications

Application
Protein Quantification
Automation Compatible
Yes
Brand
HTRF
Detection Modality
HTRF
Lysis Buffer Compatibility
Lysis Buffer 1
Lysis Buffer 4
Product Group
Kit
Sample Volume
16 µL
Shipping Conditions
Shipped in Dry Ice
Target Class
Biomarkers
Target Species
Human
Mouse
Technology
TR-FRET
Therapeutic Area
Oncology & Inflammation
Unit Size
500 Assay Points

Video gallery

How it works

Assay principle

TOM20 is measured using a sandwich immunoassay involving two specific anti-TOM20 antibodies, respectively labeled with HTRF donor and acceptor dyes. The intensity of the signal is directly proportional to the concentration of TOM20 present in the sample.

Assay principle human mouse
Assay Protocol

The two-plate protocol involves culturing cells in a 96-well plate before lysis, then transferring lysates into a 384-well low volume detection plate before the addition of TOM20 HTRF detection reagents. This protocol enables the cells' viability and confluence to be monitored.

Assay human mouse tom

 

Analytical performance

Kit characteristic
Analytical Performances
Time to results ON at RT
LOD & LOQ (in Diluent) 25 pg/mL & 45 pg/mL
Range 45 – 5000 pg/mL

 

Precision

Intra-assay (n=24)

Sample Mean [TOM20] (pg/mL) CV
1 109 5.5%
2 590 1.9%
3 2048 2.1%
  Mean CV 3.7%

 

Each of the 3 samples was measured 24 times, and the % CV was calculated for each sample.

Inter-assay (n=4)

Sample TOM20 (pg/mL) Mean (delta ratio) CV
1 156 588 11%
2 625 3604 5%
3 2500 17989 9%
      6%

 

Each of the samples was measured in 4 different experiments, and the %CV for the concentration was calculated for each sample.

 

Assay validation

Valinomycin induced mitophagy on human SH-SY5Y cell line

Neuroblastoma SH-SY5Y (human) cells were plated (50,000 cells/well) in a 96 well plate and cultured overnight in complete culture medium(DMEM/F-12, 10mM HEPES + 10%SVF) at 37°C, 5% CO2.

The day after, medium was renewed and the cells were incubated for 24h at 37°, 5% CO2, with increasing concentrations of valinomycin, a mitochondrial uncoupler. After medium removal, the cells were lysed with 50 µL of 1X supplemented lysis buffer #4 for 30 min at RT under gentle shaking, and 16 µL of lysate were transferred into a low volume white microplate followed by 4 µL of the HTRF TOM20 detection antibodies. The HTRF signal was recorded after an overnight incubation and the signals were interpolated on the TOM20 calibration curve built from serial dilution of TOM 20 standard.

An HTRF Ubiquitin Phospho-S65 assay was run on 14µL of lysates as a control for valinomycin mediated mitophagy activation.

Human mouse tom
Assay validation human mouse tom

 

Simplified pathway

Simplified Pathway

In a depolarization-induced mitophagy process, PINK1 (PTEN-induced kinase 1) linked to the outer mitochondrial membrane is activated by dimerization and autophosphorylation. Once activated, PINK-1 phosphorylates Parkin, a Ubiquitin ligase, at position Ser65 of its Ubiquitin-like domain. PINK-1 also phosphorylates ubiquitinated proteins of the outer mitochondrial membrane and among them TOM20 which once ubiquitinated is sent to proteasome. This is resulting to an increase of phospho-Ubiquitin concentration and a decrease of the TOM20 concentration.

Simplified pathway tom

 

Resources

Are you looking for resources, click on the resource type to explore further.

1-1 of 1 Resources
Guide Icon
Guide
HTRF solutions, guide to major applications

This guide provides you an overview of HTRF applications in several therapeutic areas.

Scroll Icon