Skip to main content
Menu
US

HTRF Sunitinib-Red, 20 nmol

Sunitinib-Red is a derivative of Sunitinib, and has been validated as a fluorescent tracer for HTRF Kinase Binding assays.

For research use only. Not for use in diagnostic procedures. All products to be used in accordance with applicable laws and regulations including without limitation, consumption & disposal requirements under European REACH regulations (EC 1907/2006).

Product Variants
Part number: 62KB03REDC
Unit Size: 1 nmol
List price: USD 415.40
Your price:
USD 0.00
USD 415.40 /each
Part number: 62KB03REDE
Unit Size: 20 nmol
List price: USD 5,875.00
Your price:
USD 5,875.00
USD 5,875.00 /each

Overview

This compound is derived from Sunitinib, which is a well known inhibitor of the PDGF and VEGF RTK families. Sunitinib, which is an ATP-competitive Kinase inhibitor, is used as a drug to treat renal cell carcinoma and imatinib-resistant gastrointestinal stromal tumors. It has been shown to bind with an affinity of <100 nM to about 18% of the Kinases (both RTK and Ser/Thr). It is therefore useful to address multiple Kinases in the HTRF Kinase Binding assay platform.. The ‘d2’ fluorescent dye used absorbs with its maximum near 650 nm and fluoresces near 670 nm. It is used as an acceptor molecule in HTRF assays.

Sunitinib-Red is supplied as a 25 µM solution in DMSO.

Specifications

Assay Points
20
Assay Target Type
Fluorescent reagent
Assay Technology
HTRF
Brand
HTRF
Quantity
1
Therapeutic Area
Metabolism/Diabetes
Neuroscience
Oncology & Inflammation
Unit Size
20 nmol

Video gallery

How it works

Kd determination assay principal

The binding of Sunitinib-Red is detected in a sandwich assay format using the Anti Tag labeled with Europium Cryptate (donor), which binds to the tagged Kinase, and a red fluorescent tracer labelled with d2 (acceptor).

The detection principle is based on HTRF® technology. The HTRF ratio (665/620) will increase upon the addition of more of the tracer, and will saturate depending on the dissociation constant (Kd) of the tracer to the tagged kinase.

​​​To know whether Sunitinib-Red is the tracer best suited to your tagged kinase of interest, we advise you to try the Kinase Binding Discovery kits.

kinase-binding-how-it-works-assay-principal-saturation-sunitinib-red-62kb03redc-62kb03rede.svg
 
Kd determination assay protocol

Saturation binding experiments of Sunitinib-Red can be run in 96- or 384-well plates (20 µL final volume).

First, a dilution series ranging between 0 and 1 µM of Sunitinib-Red in the Kinase Binding Buffer is prepared in a 96-well non-binding plate. Next, 5 µL of Kinase Binding Buffer are dispensed into the final 96- or 384-well plate. Then 5 µL of tagged-Kinase are added, followed by 5 µL of Anti-tag Eu-cryptate. Finally, 5 µL of the red tracer solution are added.

The HTRF ratio is measured after 1H of incubation.

IC50/Ki determination assay principle

The binding of Sunitinib-Red is detected in a sandwich assay format using a specific Anti-GST, 6HIS antibody or Streptavidin labeled with Europium Cryptate (donor), which binds to the tagged Kinase, and a red fluorescent Sunitinib labelled with d2 (acceptor).

The detection principle is based on HTRF® technology. The HTRF ratio (665/620) will increase upon the addition of more Sunitinib-Red, and will saturate depending on the dissociation constant (Kd ) of Sunitinib-Red to the tagged kinase.

When an inhibitor of the kinase is added, Sunitinib-Red will be displaced and the HTRF signal will disappear, depending on the dose.

kinase-binding-how-it-works-assay-principal-inhibition-sunitinib-red-62kb03redc-62kb03rede.svg
 
IC50/Ki determination assay protocol

​Pharmacological evaluation of inhibitors of interest can be run in 96- or 384-well plates.

First, a dilution series of inhibitor ranging between 40 µM and 0.23 nM is prepared, and 5 µL of each concentration are dispensed into the plate. Next, 5 µL of tagged-Kinase are added, followed by 5 µL of anti-tag Eu-cryptate. Finally, 5 µL of Sunitinib-Red solution are added, prepared at 4x the final concentration. The HTRF ratio is measured after 1 H of incubation.

Analyses of the data give typical dose response curves ranging between 10 µM and 56 pM, enabling an evaluation of the IC50/Ki values for the inhibitor of interest.

kinase-binding-how-it-works-assay-protocol-inhibition-sunitinib-red-62kb03redc-62kb03rede.svg

 

Assay validation

Saturation Binding (Kd)

Before perfoming competitive binding studies of inhibitors, the dissociation constant ​(Kd) of Sunitinib-Red has to be determined on the tagged Kinase of interest. This can be done with the help of the Kinase-GST/6HIS/biotin Discovery kits. A typical saturation binding experiment is performed using tracer concentrations between 0 and 250 nM, and measuring total- and non-specific binding signals. Subtracting the non-specific from the total binding signal gives the specific signal, which can be analysed to give the Kd. Here an example is shown for the  determination of the Kd (56 nM) of Sunitinib-Red on 5 nM PDGFRb-GST.

assay-validation-kinase-binding-sunitinib-red-1.svg
Competitive Binding (IC50/Ki)

Dose response curves of various known kinase inhibitors (Staurosporine, Dasatinib, Imatinib, Tozasertib, Sunitinib, and Gefitinib) were measured using Sunitinib-Red at its Kd (56 nM) on 5 nM PDGFRb-GST. Staurosporine, Dasatinib, Sunitinib, and Imatinib show show high potencies in good correlation with literature values. 

assay-validation-kinase-binding-sunitinib-red-2.svg

 

Resources

1-1 of 1 Resources
Guide Icon
Guide
HTRF solutions, guide to major applications

This guide provides you an overview of HTRF applications in several therapeutic areas.

SDS, COAs, Manuals and more Illuminator

SDS, COAs, Manuals and more

Are you looking for technical documents for this product. We have housed them in a dedicated section., click on the links below to explore.

Scroll Icon