Skip to main content
Menu
US

HTRF Streptavidin-XLent, 5,000 Assay Points

XL665-labeled Streptavidin for capturing biotinylated proteins, peptides, antibodies, small molecules, nucleic acids....

For research use only. Not for use in diagnostic procedures.

Click to copy promo code to clipboard.
SAVE 15% NOW on online orders. Use promo code below.
YEAREND15
Offer valid until 12/15. Terms and conditions apply.
Feature Specification
Application Protein-Protein Interaction

XL665-labeled Streptavidin for capturing biotinylated proteins, peptides, antibodies, small molecules, nucleic acids....

For research use only. Not for use in diagnostic procedures.

Click to copy promo code to clipboard.
SAVE 15% NOW on online orders. Use promo code below.
YEAREND15
Offer valid until 12/15. Terms and conditions apply.
Product Variants
Unit Size: 5,000 Assay Points
Part #:
611SAXLA
List Price
USD 484.64
Unit Size: 20,000 Assay Points
Part #:
611SAXLB
List Price
USD 1,551.00

Overview

Streptavidin has been labeled with XL665. The streptadivin-XLent! (SA-XLent!) results from a special in-house conjugation process leading to a high grade conjugate with enhanced fluorescent properties. Biotin binds to Streptavidin with high affinity (Ka=1015M-1). The binding is rapid and stable, making it an ideal choice for use in a variety of assays such as enzyme assays, protein-protein binding assays and molecular biology assays.

Specifications

Application
Protein-Protein Interaction
Brand
HTRF
Detection Modality
HTRF
Product Group
Fluorescent Reagent
Shipping Conditions
Shipped Ambient
Target Class
Binding Assay
Technology
TR-FRET
Therapeutic Area
Cardiovascular
Infectious Diseases
Inflammation
Metabolism/Diabetes
NASH/Fibrosis
Neuroscience
Oncology & Inflammation
Rare Diseases
Unit Size
5,000 Assay Points

Video gallery

How it works

Assay principle

In an HTRF interaction assay, one partner is labeled (directly or indirectly) with the donor, and the other with the acceptor (again, directly or indirectly). The intensity of the signal is proportional to the binding of the 2 partners. In the example shown here: Streptavidin-XLent! binds to the biotinylated partner A while partner B* binds to a specific antibody labeled to an HTRF donor. *partner B can also be tagged, Fc fused. In these cases use for the detection, the corresponding HTRF reagent (anti-Tag, anti-species, protA, Streptavidin), labeled with donor.

HTRF Streptavidin-XLent 1.svg

 

Assay protocol

The example on the right describes the protocol using a 20 µL final assay volume for detecting an interaction between a biotinylated-tagged partner A and a non-tagged partner B*. Dispense the 2 partners (10 µL), incubate, add Streptavidin-XLent! (5 µL) and anti-partner B labeled with acceptor (5 µL), incubate and read. *partner B can also be tagged, Fc fused or directly labeled. In these cases use for the detection, the corresponding HTRF reagent (anti-Tag, anti species, protA, Streptavidin), labeled with donor.

HTRF Streptavidin-XLent 2.svg

 

Assay details

Build HTRF interaction assays for your specific application

Reagents are sold by the number of tests (20 µL reactions). XL665 or d2 conjugatesare supplied on the basis of 20 ng of antibody per well. The amount of active moiety per vial is also provided (as well as the number of tracers per vial - see product description sheet). The active moiety is defined as the active part of a conjugate (e.g. antibody).

How do the number of tests relate to active moiety?

The average conjugate quantity per well reflects overall biological material content. Using the active moiety amount is generally preferred to the quantity of total conjugate. For Cryptate and d2 conjugates, the total conjugate amount equals that of the active moiety, since the molecular weight of the label is negligible. This is not the case for XL665 labeled entities for which the quantity of total conjugate will vary depending on the final molar ratio of the XL665 conjugate, however, the amount of active moiety, provided by Cisbio, is constant and based on the number of tests ordered.

Description Active Moiety/5,000 tests
Streptavidin XLent! 250 µg

 

HTRF Streptavidin-XLent 3.svg

 

Recommended quantities of Cryptate and XL665 conjugates

Cryptate conjugates must not be excessive in order to prevent reader saturation and an unacceptable level of background. In most cases, a cryptate concentration of 1 to 5nM is appropriate, and will generate 20,000 to 80,000 cps at 620 nm depending on the HTRF compatible reader used. The XL665 conjugate must match its assay counterpart as closely as possible in order for the maximum number of biomolecules to be tagged with the XL665 acceptor. Thus, to detect a tagged molecule at an assay concentration of 20nM, the concentration of anti-Tag-XL665 should be equimolar or higher.

Assay validation

HTRF Tyrosine kinase assay

HTRF reagents (Europium-Cryptate PT66 and Streptavidin-XLent!) and conjugates from two other suppliers were used in an HTRF tyrosine kinase assay. When compared to competitor, Streptavidin-XLent! shows overall superior performance.

HTRF Streptavidin-XLent 4.svg

 

SaXLent! compared to SaXL on the EGFR tyrosine kinase assay

Increasing quantities of EGFR were incubated with biotinylated polyGAT (50 nM). The enzymatic reaction was stopped using EDTA following a 20 minute incubation. Europium-labeled PT66 (20 ng/well) and Streptavidin-XL665 (50 nM) or StreptavidinXLent! (50 nM) were added. HTRF signal was detected following a 20 minute incubation. In addition to the increased sensitivity, over 25% less enzyme was required when using streptavidin-XLent! to produce identical assay signals.

HTRF Streptavidin-XLent 5.svg

 

Resources

Are you looking for resources, click on the resource type to explore further.

1-1 of 1 Resources
Brochure Icon
Brochure
HTRF assays and reagents catalog

Discover the versatility and precision of Homogeneous Time-Resolved Fluorescence (HTRF) technology. Our HTRF portfolio offers a...

Scroll Icon