Skip to main content
Menu
US

Operetta CLS High-Content Analysis System

Uncover deep biological understanding in your everyday assays and innovative applications using the Operetta CLS™ high-content analysis system. Featuring a unique combination of technologies, the system delivers all the speed, sensitivity and resolution you need to reveal fine sub-cellular details. And with our simple, powerful Harmony software, Operetta CLS™ lets you find even subtle phenotypic changes.

For research use only. Not for use in diagnostic procedures.

Product Variant
Unit Size: 1 Unit
Part #:
HH16000020

Overview

The Operetta CLS system combines speed and sensitivity with the powerful and intuitive data analysis you’ve come to trust from the Operetta platform. The all-new Operetta CLS delivers everything you need from the high-content analysis. What’s more, the Operetta CLS system is part of our comprehensive HCS workflow – everything from HCS systems and microplates to automation and informatics for every application. All from one knowledgeable, trusted vendor. Put that together with our Harmony™
high-content imaging and analysis software – the easy-to-learn, easy-to-use software that empowers biologists to do their own analysis – and you have everything you need to run your every day (and complex) analyses right away.

Applications

From everyday assays to more demanding applications, the Operetta CLS high-content analysis system delivers just the right combination of flexible excitation, sensitive optics, and advanced software features to enable you to gain deeper biological insight from all your critical applications.

Fixed-cell assays

  • Up to eight high-power excitation sources and user-accessible emission filters enable maximum flexibility of fluorescent stains and labels, plus the system features widefield and spinning-disk fluorescent imaging.

Live-cell assays

  • The spinning disk confocal optics and synchronized LED illumination provides stable excitation and minimize phototoxicity and bleaching for meaningful live-cell assays. You can also choose brightfield or digital-phase contrast imaging modes.

Complex cellular models

  • The large-format sCMOS camera with water-immersion objectives provides sensitivity and high resolution, while advanced software helps you address the imaging and analysis challenges presented by complex cellular models.

Advanced assays

  • FRET is a powerful tool for investigating conformational changes and protein-protein interactions. The Operetta CLS system’s sensitive imaging and dedicated analysis tools for ratiometric imaging, facilitate robust results.

Phenotypic fingerprinting

  • The Operetta CLS combines high-resolution imaging with advanced software tools to help create robust phenotypic fingerprints of the subtle differences at the core of successful phenotypic assays.
Your complete HCS workflow
  • Get superior results with our PhenoPlate™ microplates for high content screening
  • Use together with our PhenoVue™ cellular imaging reagents including cell painting kits
  • Improve throughput and productivity by automating your Operetta CLS system, or benefit from our automated cellular workflows and drug discovery workflows
  • Export results automatically into Signals Image Artist™ Image Analysis and Management platform, so you can access, re-analyze, store, and share all your cell image data from Operetta CLS and other HCS systems
  • Combine with Signals VitroVivo for powerful multivariate statistical methods and unsupervised machine learning techniques so you can identify parameters that best define distinct cellular fingerprints

Additional product information

Operetta CLS is a high throughput microplate imager for high-content analysis (HCA). It can acquire, analyze and manage fluorescence, brightfield and digital phase contrast images. The combination of high power LED excitation with fast, precise mechanics and one large format sCMOS camera enables fast imaging. Controlled by Harmony software it offers a seamless workflow, for reliable discrimination of phenotypes even in complex cellular models

Features at a glance
 

Intelligent image acquisition

Intelligent image acquisition

Target more accurately your object of interest for significantly reduced acquisition and analysis times, particularly valuable for 3D microtissue and rare event studies.

Machine learning

Machine learning

Easily create algorithms without being an image analysis expert using our PhenoLOGIC proprietary machine-learning technology.

Easily Quantify Cellular Phenotypes in Complex 3D Models

Easily quantify cellular phenotypes in complex 3D models

Explore your cell models by visualizing them in a 3D- and an XYZ-viewer and quantify volumetric and other 3D related phenotypic readouts.

Powerfully simple analysis capabilities

Powerfully simple analysis capabilities

Harmony® high-content imaging and analysis software - is the easy-to-learn, easy-to-use software that can make you more productive - faster.

High efficiency excitation design

High efficiency excitation design

Direct coupling limits the light loss that is typical of light guides or fibers.

Fast Frame Rate Imaging

Fast Frame Rate Imaging

Capture rapid cellular changes with an imaging frame rate up to 105 fps.

Automated water-immersion objectives

Automated water-immersion objectives

From the company with more than 20 years of experience - giving faster exposure times, increased resolution and reduced photodamage.

Confocal spinning-disk technology

Confocal spinning-disk technology

Provides a gentle imaging process (especially for live-cell experiments) with efficient background rejection.

 

 

operetta cls banner

 

Customer testimonials

A solution configured to suit every need

Whatever your application, there’s an Operetta CLS system configured to meet your requirements. And it’s modular, so it can change with your research demands.

Operetta CLS configurations

Quattro

Operetta® CLS Quattro

Ideal for common applications that need sensitivity and resolution, with the capacity to grow if the need arises.

FLEX

Operetta® CLS FLEX

Offers flexibility in excitation and imaging modes for many challenging applications – and it can be upgraded to even higher performance.

LIVE

Operetta® CLS LIVE

Ideal for gentle yet highly sensitive live-cell imaging.

    Quattro FLEX LIVE
System Options Camera sCMOS sCMOS sCMOS
Number of LEDs 4 8 8
Confocal Disk º
Environmental Control º º
Water Immersion º º
Transmitted Light
Robotics/Automation Compatible
Imaging Modes Fluorescence Widefield Imaging
Confocal Flourescence º
Brightfield and Digital Phase Contrast
Ratiometric FRET
3D Imaging º
Live-Cell Imaging º º

• Includedº Optional

Specifications

Dimensions 66.0 cm (W) x 98.0 cm (D) x 45.0 cm (H)
21CFR Compatible
No
Automation Compatible
Yes
Brand
Operetta CLS
Detection Modality
Fluorescence
Fluorescence Transmittance
Transmission
Unit Size
1 Unit

Video gallery

Resources

Are you looking for resources, click on the resource type to explore further.

1-6 of 59 Resources
Application Note Icon
Application Note
3D Analysis of Cell Invasion using Operetta

Here, we present a method for analyzing cell invasion into a 3D extracellular matrix using the Operetta® high-content analysis...

Brochure Icon
Brochure
3D cell culture workflow solutions

More than ever, researchers are turning to 3D cell cultures, microtissues and organoids to bridge the gap between 2D cell cultures...

Technical Note Icon
Technical Note
3D volumetric analysis of luminal spaces inside cysts or organoids

High-content assays using 3D objects such as cysts or organoids can be challenging from the perspectives of both image acquisition...

Technical Note Icon
Technical Note
3D volumetric and zonal analysis of solid spheroids

Multicellular 3D “oids” (tumoroids, spheroids, organoids) have the potential to better predict the effects of drug candidates...

Application Note Icon
Application Note
A multiparametric live-cell cytotoxicity analysis using the Operetta High-content Analysis System

The detection of compound cytotoxicity is an essential part of drug discovery. In this work we describe a rapid and flexible image...

Case Study Icon
Case Study
A workflow to characterize and benchmark human induced pluripotent stem cells

The UK-based Human Induced Pluripotent Stem Cell Initiative (HipSci) aims to offer the scientific community access to a vast panel...

Scroll Icon