Skip to main content
Menu
US

Test of Vitamin D

Omics test Model
Test Code VS
Test Summary Detecting Vitamin D by tandem mass spectrometry.
Turn Around Time 4 days
Acceptable Sample Types Dried Blood Spots
NY Approved No
*TAT starts after the sample and all required sample information is received at the processing laboratory.

**The CPT codes listed are in accordance with Current Procedural Terminology, a publication of the American Medical Association, and are provided for informational purposes only. CPT coding is the sole responsibility of the billing party.

This testing service has not been cleared or approved by the U.S. Food and Drug Administration. Testing services may not be licensed in accordance with the laws in all countries. The availability of specific test offerings is dependent upon laboratory location.
This test is not available in your region United States, please select your nearest laboratory to request more information.
Revvity Sites Globally

Select your location.

Test Description

Use MSMS to assist the diagnosis of vitamin D deficiency; Guide treatment and evaluate therapeutic effect.

Indications for Testing

  • Children over 1 year old.
  • Pregnant women.
  • Elderly people.
  • Perimenopausal women.
  • Adults who are suspected of vitamin D deficiency.

Condition Description

Vitamin D deficiency is the most common nutritional deficiency worldwide, characterised by serum 25-hydroxyvitamin D <50 nanomoles/L (<20 nanograms/mL). Vitamin D insufficiency is regarded as a serum 25-hydroxyvitamin D concentration between 52-72 nanomoles/L (21-29 nanograms/mL).
Main causes include sun avoidance, increased skin pigmentation, inadequate dietary and supplemental vitamin D intake, malabsorption syndromes, obesity, and medication use. Acquired and inherited disorders that either reduce or prevent the metabolism of 25-hydroxyvitamin D to 1,25-dihydroxyvitamin D also present with biochemical and skeletal abnormalities seen with vitamin D deficiency, but in a more severe form.

Test Methods and Limitations

Tandem mass spectrometry analysis can be coupled with liquid chromatography, a technique referred to as LC-MS/MS. In this methodology, chromatography is used to separate analytes of interest prior to measurement by the mass spectrometer. This separation reduces interference from matrix components and can also allow for the measurement of analytes that have the same mass (isobaric species), thereby improving analytical specificity compared to MS/MS.

Detailed Sample Requirements

Dried Blood Spots
Test Details Page
Collection Container(s) Dried blood spot card
Collection

Follow kit instructions. Briefly, allow blood to saturate the card until indicated areas are filled and blood has soaked through the card. Air dry the card at ambient temperature for at least 3 hours.

  • NBS: Please contact Revvity Omics to request the StepOne® kit.
  • Gene Sequencing: Please contact Revvity Omics to request the DBS collection kit.
  • For pre-punched DBS: The required minimum is 6 punches
Sample Condition Follow the instructions provided with the collection set. Store the dried blood at ambient temperature for up to two days. If the specimen cannot be sent as soon as it is dry, the filter paper should be placed in a sealable plastic bag and stored in a refrigerator (≤ 8°C) or preferably in a freezer.
Shipping Follow kit instructions. Double bag and ship overnight at ambient temperature.