Skip to main content
Menu
US

ACID Sphingomyelinase Enzyme Analysis

Omics test Model
Test Code B0017
Test Summary

This test detects acid sphingomyelinase activity.

Turn Around Time 3 days
Acceptable Sample Types Dried Blood Spots , Whole Blood (EDTA)
Acceptable Billing Types Institutional Billing , Self (patient) Payment
NY Approved Yes
Self (patient) Price $108.90
Institutional Price $108.90
*TAT starts after the sample and all required sample information is received at the processing laboratory.

**The CPT codes listed are in accordance with Current Procedural Terminology, a publication of the American Medical Association, and are provided for informational purposes only. CPT coding is the sole responsibility of the billing party.

This testing service has not been cleared or approved by the U.S. Food and Drug Administration. Testing services may not be licensed in accordance with the laws in all countries. The availability of specific test offerings is dependent upon laboratory location.

Test Description

This test detects acid sphingomyelinase enzyme activity that has been associated with Niemann-Pick disease type A and type B.

Indications for Testing

This test may be appropriate for individuals with a clinical suspicion of Niemann-Pick disease type A and type B and/or individuals with a family history of this condition.

Condition Description

Niemann-Pick disease type A and type B are lysosomal storage disorders that has a wide range of symptoms that vary in severity. Symptoms of this condition may include hepatosplenomegaly, failure to thrive, loss of milestones, lung disease and a cherry-red spot on eye exam. Niemann-Pick disease types A and B is estimated to affect 1/250,000 individuals and is more frequent in the Ashkenazi Jewish population.

Test Methods and Limitations

Tandem mass spectrometry analysis can be coupled with liquid chromatography, a technique referred to as LC-MS/MS. In this methodology, chromatography is used to separate analytes of interest prior to measurement by the mass spectrometer. This separation reduces interference from matrix components and can also allow for the measurement of analytes that have the same mass (isobaric species), thereby improving analytical specificity compared to MS/MS.

Detailed Sample Requirements

Whole Blood (EDTA)
Test Details Page
Collection Container(s) EDTA (purple top)
Collection Infants (< 2-years): 2 to 3 mL; Children (>2-years): 3 to 5 mL; Older children and adults: Minimum 5mL. The blood tube should be inverted several times immediately after blood collection to prevent coagulation.
Sample Condition Store at ambient temperature. Do not refrigerate or freeze.
Shipping Ship overnight at ambient temperature ensuring receipt within 5-days of collection.
Special Sample Instructions Clotted or hemolyzed samples are not accepted.
Dried Blood Spots
Test Details Page
Collection Container(s) Dried blood spot card
Collection

Follow kit instructions. Briefly, allow blood to saturate the card until indicated areas are filled and blood has soaked through the card. Air dry the card at ambient temperature for at least 3 hours.

  • NBS: Please contact Revvity Omics to request the StepOne® kit.
  • Gene Sequencing: Please contact Revvity Omics to request the DBS collection kit.
  • For pre-punched DBS: The required minimum is 6 punches
Sample Condition Follow the instructions provided with the collection set. Store the dried blood at ambient temperature for up to two days. If the specimen cannot be sent as soon as it is dry, the filter paper should be placed in a sealable plastic bag and stored in a refrigerator (≤ 8°C) or preferably in a freezer.