Human E-cadherin standard, for use in running standard curves in LANCE Ultra TR-FRET assays. This standard is already provided in the LANCE Ultra Human E-cadherin TR-FRET Detection Kit, but can also be ordered separately.
Feature | Specification |
---|---|
Application | Protein Quantification |
Dynamic Range | 23.0 - 30,000 pg/mL |
Limit of Detection | 23 pg/mL |
Limit of Quantification | 123 pg/mL |
Sample Volume | 15 µL |
Human E-cadherin standard, for use in running standard curves in LANCE Ultra TR-FRET assays. This standard is already provided in the LANCE Ultra Human E-cadherin TR-FRET Detection Kit, but can also be ordered separately.
The LANCE® Ultra Human E-cadherin Detection Kit is designed for detection and quantitation of human insulin in cell culture media and cell lysates using a homogeneous TR-FRET (no-wash steps, no separation steps) assay.
LANCE and LANCE (Lanthanide chelate excite) Ultra are our TR-FRET (time-resolved fluorescence resonance energy transfer), homogeneous (no wash) technologies. One antibody of interest is labeled with a donor fluorophore (a LANCE Europium chelate) and the second molecule is labeled with an acceptor fluorophore (ULight™ dye). Upon excitation at 320 or 340 nm, energy can be transferred from the donor Europium chelate to the acceptor fluorophore if sufficiently close for FRET (~10 nm). This results in the emission of light at 665 nm.
Epithelial Cadherin (E-Cadherin), also known as Cadherin-1 or Uvomorulin (in mouse and rat) is a single-pass transmembrane protein that facilitates calcium dependent cell adhesion. A member of the Cadherin family, E-Cadherin utilizes five extracellular EC domains to form cis-clusters between adjacent epithelial cells and trans-clusters within the same cell. Cleavage of the N-terminal domain by a number of proteases is critical for cell motility and EGFR-dependent survival. The intracellular domain of E-cadherin interacts with many proteins including β-catenin, α-catenin, vinculin, and plakoglobin. Lack of binding to any of these proteins has been indicated in cancer metastasis.
Application |
Protein Quantification
|
---|---|
Automation Compatible |
Yes
|
Brand |
LANCE Ultra
|
Detection Modality |
LANCE
|
Dynamic Range |
23.0 - 30,000 pg/mL
|
Limit of Detection |
23 pg/mL
|
Limit of Quantification |
123 pg/mL
|
Product Group |
Kit
|
Sample Volume |
15 µL
|
Shipping Conditions |
Shipped in Blue Ice
|
Target |
E-Cadherin
|
Target Class |
Biomarkers
|
Target Species |
Human
|
Technology |
TR-FRET
|
Therapeutic Area |
Oncology
|
Unit Size |
500 Assay Points
|