The LANCE® Ultra Human Albumin Detection Kit is designed for detection and quantitation of human albumin in cell culture media using a homogeneous TR-FRET (no-wash steps, no separation steps) assay.
For research use only. Not for use in diagnostic procedures. All products to be used in accordance with applicable laws and regulations including without limitation, consumption and disposal requirements under European REACH regulations (EC 1907/2006).
Feature | Specification |
---|---|
Application | Protein Quantification |
Dynamic Range | 68.1- 100,000 pg/mL |
Limit of Detection | 68.1 pg/mL |
Limit of Quantification | 369.2 pg/mL |
Sample Volume | 15 µL |
The LANCE® Ultra Human Albumin Detection Kit is designed for detection and quantitation of human albumin in cell culture media using a homogeneous TR-FRET (no-wash steps, no separation steps) assay.
For research use only. Not for use in diagnostic procedures. All products to be used in accordance with applicable laws and regulations including without limitation, consumption and disposal requirements under European REACH regulations (EC 1907/2006).
The LANCE® Ultra Human Albumin Detection Kit is designed for detection and quantitation of human albumin in cell culture media using a homogeneous TR-FRET (no-wash steps, no separation steps) assay.
LANCE® and LANCE® (Lanthanide chelate excite) Ultra are our TR-FRET (time-resolved fluorescence resonance energy transfer), homogeneous (no wash) technologies. One antibody of interest is labeled with a donor fluorophore (a LANCE Europium chelate) and the second molecule is labeled with an acceptor fluorophore (ULight™ dye). Upon excitation at 320 or 340 nm, energy can be transferred from the donor Europium chelate to the acceptor fluorophore if sufficiently close for FRET (~10 nm). This results in the emission of light at 665 nm.
Human serum albumin (HSA) is a 66 kDa protein produced by the liver. HSA constitutes two thirds of the protein mass of serum and plays a key role in the transport of small molecules in the blood such as fatty acids, vitamins, hormones, divalent cations, and drugs. Another important function of HSA is to maintain osmotic pressure and pH in the blood. HSA is an important biomarker in kidney disease. In albuminuria, albumin is not reabsorbed properly by kidney glomeruli and is excreted in the urine. Generally, in hypoalbuminemia, a lower level of albumin in serum can be explained by a kidney disease, poor liver function, or inflammation.
Application |
Protein Quantification
|
---|---|
Automation Compatible |
Yes
|
Brand |
LANCE Ultra
|
Detection Modality |
LANCE
|
Dynamic Range |
68.1- 100,000 pg/mL
|
Limit of Detection |
68.1 pg/mL
|
Limit of Quantification |
369.2 pg/mL
|
Product Group |
Kit
|
Sample Volume |
15 µL
|
Shipping Conditions |
Shipped in Blue Ice
|
Target |
Albumin
|
Target Class |
Biologics
|
Target Species |
Human
|
Technology |
TR-FRET
|
Therapeutic Area |
Metabolic
|
Unit Size |
10,000 Assay Points
|
Are you looking for resources, click on the resource type to explore further.
LANCE™ Ultra TR-FRET is a no-wash proximity assay technology that combines the benefits of time resolution (TR) with fluorescence...
We are here to answer your questions.