Europium-labeled anti-phosphotyrosine (P-Tyr-100) antibody, for use in LANCE® TR-FRET kinase assays.
For research use only. Not for use in diagnostic procedures. All products to be used in accordance with applicable laws and regulations including without limitation, consumption and disposal requirements under European REACH regulations (EC 1907/2006).
Feature | Specification |
---|---|
Application | Biochemical Enzymatic Assay |
Europium-labeled anti-phosphotyrosine (P-Tyr-100) antibody, for use in LANCE® TR-FRET kinase assays.
For research use only. Not for use in diagnostic procedures. All products to be used in accordance with applicable laws and regulations including without limitation, consumption and disposal requirements under European REACH regulations (EC 1907/2006).
Generic LANCE® reagents are intended for setting up homogeneous time-resolved fluorescence resonance energy transfer (TR-FRET) based assays using Eu-Chelate label as a donor and APC-labeled reagent as an acceptor. Generic reagents facilitate setting up LANCE® assays when there is a limited amount of specific reagents available or the assay reagents are relatively unstable. To enable optimization of both the signal or the noise ratio and signal stability, some of the generic reagents are labeled with two different chelates, W1024 or W8044.
LANCE® (Lanthanide chelate excite) and LANCE® Ultra are our TR-FRET (time-resolved fluorescence resonance energy transfer), homogeneous (no wash) technologies. One molecule of interest is labeled with a donor fluorophore (a LANCE Europium chelate) and the second molecule is labeled with an acceptor fluorophore [ULight™ dye, allophycocyanin (APC), etc.]. Upon excitation at 320 or 340 nm, energy can be transferred from the donor Europium chelate to the acceptor fluorophore if sufficiently close for FRET (~10 nm). This results in the emission of light at 665 nm (for ULight dye and APC).
Application |
Biochemical Enzymatic Assay
|
---|---|
Automation Compatible |
Yes
|
Brand |
LANCE
|
Conjugates |
Anti-P-Tyr-100
|
Detection Modality |
LANCE
|
Fluorophore |
Eu-W1024
|
Molecular Modification |
Phosphorylation
|
Product Group |
Antibody
|
Shipping Conditions |
Shipped in Blue Ice
|
Target Class |
Kinases
|
Technology |
TR-FRET
|
Unit Size |
50 µg
|
Are you looking for resources, click on the resource type to explore further.
LANCE™ Ultra TR-FRET is a no-wash proximity assay technology that combines the benefits of time resolution (TR) with fluorescence...
This note presents a method to evaluate inhibitors of p38 kinase activity using LANCE. We are measuring energy transfer from a Eu...