Terbium cryptate labeling kit tailored for biomolecule labeling and straightforward development of time-resolved fluorescence resonance energy transfer assays.
For research use only. Not for use in diagnostic procedures. All products to be used in accordance with applicable laws and regulations including without limitation, consumption and disposal requirements under European REACH regulations (EC 1907/2006).
Feature | Specification |
---|---|
Application | Labeling |
Terbium cryptate labeling kit tailored for biomolecule labeling and straightforward development of time-resolved fluorescence resonance energy transfer assays.
For research use only. Not for use in diagnostic procedures. All products to be used in accordance with applicable laws and regulations including without limitation, consumption and disposal requirements under European REACH regulations (EC 1907/2006).
The Cryptate labeling kit is suitable for quick, easy labeling of peptides, proteins, and oligonucleotides with Terbium cryptate. This kit is designed for very small-volume fast labeling needs, such as determining the best antibody among several antibodies available for HTRF assay development. The N-hydroxysuccinimide activated Terbium-Trisbipyridine (TBP) supplied reacts with primary amines carried by the biomolecules to label, for simplified conjugation. The kit includes all the materials necessary for the labeling procedure (except dialysis and concentration devices).
Application |
Labeling
|
---|---|
Brand |
HTRF
|
Detection Modality |
HTRF
|
Product Group |
Fluorescent Reagent
|
Shipping Conditions |
Shipped Ambient
|
Technology |
TR-FRET
|
Unit Size |
1 Vial
|
The labeling procedure is performed under very mild conditions. As shown here, the process includes an incubation step with the desiccated dye, followed by purification on a disposable column. Both the purification column and the buffer for purifying the conjugate are included in the kit, as well as a calibrator to define the ideal working dilution of the labeled material in HTRF assays. Depending on the molecular weight of the target molecule and the nature of the dye, each kit enables the labeling of 5-25 µg (protein-MW 15 kDa) to 50-250 µg (antibody-MW 150 kDa).
The labeling procedure is described on the right. 75 µL of the targeted molecule (6.67 µM) in phosphate buffer pH 8.0 are added to the Terbium cryptate vial. After an incubation of 15 min at RT, labeled protein is eluted on an equilibrated column. After having discarded 700 µL of elution buffer, the labeled molecule is collected in a 400 µL fraction.
Are you looking for resources, click on the resource type to explore further.
Discover the versatility and precision of Homogeneous Time-Resolved Fluorescence (HTRF) technology. Our HTRF portfolio offers a...
This guide provides you an overview of HTRF applications in several therapeutic areas.
We are here to answer your questions.