High Resolution LabChip GXII, Touch HT

The High Resolution LabChip® is designed to be compatible with the Glycan Screening Assay and Low Molecular Weight Protein Assay on the LabChip® GXII microfluidic capillary electrophoresis (CE-SDS) platform. This chip is available in a single pack.

For research use only. Not for use in diagnostic procedures.

Product Variants
Application: Protein Analysis
Instrument Compatibility
LabChip GXII Touch HT
Part #:
760524
List Price
USD 1,398.00
Application: Protein Analysis
Instrument Compatibility
LabChip GXII Touch 24
Part #:
CLS138951
List Price
USD 869.62
Feature Specification
Linear Concentration Range LMW Protein 30 - 2000 ng/µL (BLG, CAII in PBS), GLycanb 1.25 - 7.5mg/mL,
Percent Purity Reproducibility LMW Protein 30% CV ≤ 80 kDa., HT Glycan: CV < 10% for a peak ≥ 2.5% of total glycans, HT Glycan Extended Range: CV < 10% for a peak ≥ 2.5% of total glycans and at a conc. 2.5 ng/L CV < 25% for a peak ≥ 2.5% of total glycans at conc. 1.0 - 2.5 ng/µL
Sample Type Glycan
Protein
Size Range LMW Protein Express 5 - 80 kDa, HT Glycan: neutral glycans found on mAbs, some charged glycans may run outside of our usable range HT Glycan Extended Range: neutral and charged glycans found on mAbs
Sizing Precision RSD (CV) LMW Protein ± 20% up to 80 kDa ± 10% (CAII, BLG), Glycan CV < 2.5%
Sizing Resolution LMW Protein ± 10% 14 - 80 kDa ± 20% < 14 kDa
Unit Size 1 chip
Feature Specification
Linear Concentration Range LMW Protein 30 - 2000 ng/µL (BLG, CAII in PBS), GLycanb 1.25 - 7.5mg/mL,
Percent Purity Reproducibility LMW Protein 30% CV ≤ 80 kDa., HT Glycan: CV < 10% for a peak ≥ 2.5% of total glycans, HT Glycan Extended Range: CV < 10% for a peak ≥ 2.5% of total glycans and at a conc. 2.5 ng/L CV < 25% for a peak ≥ 2.5% of total glycans at conc. 1.0 - 2.5 ng/µL
Sample Type Glycan
Protein
Size Range LMW Protein Express 5 - 80 kDa, HT Glycan: neutral glycans found on mAbs, some charged glycans may run outside of our usable range HT Glycan Extended Range: neutral and charged glycans found on mAbs
Sizing Precision RSD (CV) LMW Protein ± 20% up to 80 kDa ± 10% (CAII, BLG), Glycan CV < 2.5%
Sizing Resolution LMW Protein ± 10% 14 - 80 kDa ± 20% < 14 kDa
Unit Size 1 chip

Overview

The High Resolution LabChip® is designed to be compatible with the Glycan Screening Assay and Low Molecular Weight Protein Assay on the LabChip GXII Touch protein characterization system.

This chip works with the following Reagent kits (sold separately):

  • Glycan Screening Reagent Kit (P/N 760525)
  • Low Molecular Weight Protein Reagent Kit (P/N 760573)

Specifications

Application
Protein Analysis
Automation Compatible
Yes
Instrument Compatibility
LabChip GXII Touch HT
Linear Concentration Range
LMW Protein 30 - 2000 ng/µL (BLG, CAII in PBS), GLycanb 1.25 - 7.5mg/mL,
Percent Purity Reproducibility
LMW Protein 30% CV ≤ 80 kDa., HT Glycan: CV < 10% for a peak ≥ 2.5% of total glycans, HT Glycan Extended Range: CV < 10% for a peak ≥ 2.5% of total glycans and at a conc. 2.5 ng/L CV < 25% for a peak ≥ 2.5% of total glycans at conc. 1.0 - 2.5 ng/µL
Sample Type
Glycan
Protein
Sample Volume
LMW Protein 2 µL, Glycan 8µL
Size Range
LMW Protein Express 5 - 80 kDa, HT Glycan: neutral glycans found on mAbs, some charged glycans may run outside of our usable range HT Glycan Extended Range: neutral and charged glycans found on mAbs
Sizing Precision RSD (CV)
LMW Protein ± 20% up to 80 kDa ± 10% (CAII, BLG), Glycan CV < 2.5%
Shipping Conditions
Shipped in Blue Ice Soft
Sizing Resolution
LMW Protein ± 10% 14 - 80 kDa ± 20% < 14 kDa
Technology
Microfluidic Electrophoresis
Unit Size
1 chip

Resources

Are you looking for resources, click on the resource type to explore further.

1-1 of 1 Resources
Product Note Icon
Product Note
Automated characterization of proteins and nucleic acids

Read the LabChip® GXII Touch protein characterization system product note to learn about an automated alternative to traditional...