DNA Reagent for the DNA 12K LabChip kit. Contains enough reagent for 2000 wells. The DNA 12K LabChip kit for use on the LabChip® GX and LabChip GX Touch systems provides a fast and easy way to analyze a DNA samples ranging from 100 to 12,000 base pairs, which is an extended size range relative to the companion assays in the Revvity portfolio.
For research use only. Not for use in diagnostic procedures.
Feature | Specification |
---|---|
Analytical Sensitivity | 0.25 ng/µL |
Application | DNA Analysis |
Automation Compatible | Yes |
Instrument Compatibility |
LabChip GXII Touch LabChip GX Touch |
Linear Concentration Range | 0.25 ng/µL - 50 ng/µL per fragment |
Percent Purity Reproducibility | 20% CV from 100 - 5000 bp 25% CV from 5000 - 1200 bp |
Size Range | 100 - 12000 bp |
Sizing Precision RSD (CV) | ± 10% |
Sizing Resolution | ± 10% from 150 - 1000 bp ± 15% from 1000 - 2000 bp ± 20% from 2000 - 8000 bp ± 25% from 100 - 150 bp, 8000 - 12000 bp |
Unit Size | 2000 samples |
DNA Reagent for the DNA 12K LabChip kit. Contains enough reagent for 2000 wells. The DNA 12K LabChip kit for use on the LabChip® GX and LabChip GX Touch systems provides a fast and easy way to analyze a DNA samples ranging from 100 to 12,000 base pairs, which is an extended size range relative to the companion assays in the Revvity portfolio.
For research use only. Not for use in diagnostic procedures.
Performing DNA sample analysis with the DNA 12K assay saves time and money by automating steps for analyzing size and purity, and replaces agarose slab gels, and imaging.
The LabChip® GX and GX Touch instruments use a single sipper microfluidic chip to aspirate dsDNA samples directly from 96- or 384-well plates. The microfluidics chip technology automatically mixes in an intercolating dye, electrophoretically separates, and analyzes the DNA sample. The instrument optics detect the laser-induced fluorescent signal. System software automatically analyzes the data and determines fragment size and concentration using ladder and marker calibration standards. Digital data results are immediately available for review or reporting in virtual gel, electropherogram graph, or table summary form.
Chip and Reagents sold separately: DNA Extended Range Chip (P/N 760517, LabChip GX, LabChip GX Touch HT P/N CLS 138948, LabChip GX Touch 24 ) DNA 12K Reagent (P/N 760569)
Additional Specifications
Sizing Range - 100 bp – 12000 bp
Sizing Accuracy - ± 10%
Sizing Resolution - ± 10% from 150 – 1000 bp, ± 15% from 1000 – 2000 bp, ± 20% from 2000 – 8000 bp, ± 25% from 100 – 150 bp, 8000 – 12000 bp
Linear Concentration Range – 0.25 ng/µL – 50 ng / µL Per fragment
Sensitivity – 0.25 ng / µL
Chip Sample Lifetime – 2000
Analytical Sensitivity |
0.25 ng/µL
|
---|---|
Application |
DNA Analysis
|
Automation Compatible |
Yes
|
Instrument Compatibility |
LabChip GXII Touch
LabChip GX Touch
|
Linear Concentration Range |
0.25 ng/µL - 50 ng/µL per fragment
|
Percent Purity Reproducibility |
20% CV from 100 - 5000 bp 25% CV from 5000 - 1200 bp
|
Sample Type |
DNA
|
Size Range |
100 - 12000 bp
|
Sizing Precision RSD (CV) |
± 10%
|
Shipping Conditions |
Shipped in Blue Ice Soft
|
Sizing Resolution |
± 10% from 150 - 1000 bp ± 15% from 1000 - 2000 bp ± 20% from 2000 - 8000 bp ± 25% from 100 - 150 bp, 8000 - 12000 bp
|
Technology |
Microfluidic Electrophoresis
|
Throughput |
68 sec
|
Unit Size |
2000 samples
|