The combined HT DNA 5K/HT RNA LabChip for use on the LabChip GX and GXII systems provides a fast and easy way to analyze DNA and RNA samples.
For research use only. Not for use in diagnostic procedures.
Feature | Specification |
---|---|
Analytical Sensitivity | DNA 0.25 ng/µL, Pico RNA 250 pg/µL Total RNA, Small RNA 50 pg/μL, 500 pg/µL mRNA |
Application |
DNA Analysis Protein Analysis RNA Analysis |
Linear Concentration Range | DNA 0.25 - 50 ng/µL 0.2 per fragment, RNA 25 - 250 ng/ μL (Std Sens) and 5 - 50 ng/μL (High Sens), Pico RNA 500 - 5,000 pg/µL Total RNA 625 - 5000 pg/µL mRNA, small RNA 100-10,000 pg/ul, Protein 25 µL with concentration between 0.5 - 10 mg/mL |
Size Range | DNA 100 - 5,000 bp, RNA 100 - 6,000 nt, Small RNA 20 - 150 nt |
Sizing Precision RSD (CV) | DNA ± 10%, small RNA CV < 5.0% or 4 nt, Protein CV < 5% for varying concentration from 1 - 3 mg/mL CV < 3% at constant concentration |
Sizing Resolution | DNA ± 10% from 150 - 500 bp ± 15% from 100 - 150 bp, 500 - 1500 bp ± 20% from 1500 - 5000 bp, Protein Comparable to IEX and conventional CZE |
Feature | Specification |
---|---|
Analytical Sensitivity | DNA 0.25 ng/µL, Pico RNA 250 pg/µL Total RNA, Small RNA 50 pg/μL, 500 pg/µL mRNA |
Application |
DNA Analysis Protein Analysis RNA Analysis |
Linear Concentration Range | DNA 0.25 - 50 ng/µL 0.2 per fragment, RNA 25 - 250 ng/ μL (Std Sens) and 5 - 50 ng/μL (High Sens), Pico RNA 500 - 5,000 pg/µL Total RNA 625 - 5000 pg/µL mRNA, small RNA 100-10,000 pg/ul, Protein 25 µL with concentration between 0.5 - 10 mg/mL |
Size Range | DNA 100 - 5,000 bp, RNA 100 - 6,000 nt, Small RNA 20 - 150 nt |
Sizing Precision RSD (CV) | DNA ± 10%, small RNA CV < 5.0% or 4 nt, Protein CV < 5% for varying concentration from 1 - 3 mg/mL CV < 3% at constant concentration |
Sizing Resolution | DNA ± 10% from 150 - 500 bp ± 15% from 100 - 150 bp, 500 - 1500 bp ± 20% from 1500 - 5000 bp, Protein Comparable to IEX and conventional CZE |
The DNA 5K / RNA / Charge Variant Assay LabChips are only prepped once per day, supporting a variety of samples workflows, have a long sample life, and are able to be reused multiple days to lower your per sample costs.
Analytical Sensitivity |
DNA 0.25 ng/µL, Pico RNA 250 pg/µL Total RNA, Small RNA 50 pg/μL, 500 pg/µL mRNA
|
---|---|
Application |
DNA Analysis
Protein Analysis
RNA Analysis
|
Automation Compatible |
Yes
|
Instrument Compatibility |
LabChip GXII Touch
LabChip GX Touch
|
Linear Concentration Range |
DNA 0.25 - 50 ng/µL 0.2 per fragment, RNA 25 - 250 ng/ μL (Std Sens) and 5 - 50 ng/μL (High Sens), Pico RNA 500 - 5,000 pg/µL Total RNA 625 - 5000 pg/µL mRNA, small RNA 100-10,000 pg/ul, Protein 25 µL with concentration between 0.5 - 10 mg/mL
|
Sample Type |
DNA
Protein
RNA
|
Sample Volume |
DNA 2 μL, RNA 2 μL RNA Std Sens or 6 μL RNA High Sens. Pico RNA 2 μL, Small RNA 2 μL, Protein 25 μL
|
Size Range |
DNA 100 - 5,000 bp, RNA 100 - 6,000 nt, Small RNA 20 - 150 nt
|
Sizing Precision RSD (CV) |
DNA ± 10%, small RNA CV < 5.0% or 4 nt, Protein CV < 5% for varying concentration from 1 - 3 mg/mL CV < 3% at constant concentration
|
Shipping Conditions |
Shipped in Blue Ice Soft
|
Sizing Resolution |
DNA ± 10% from 150 - 500 bp ± 15% from 100 - 150 bp, 500 - 1500 bp ± 20% from 1500 - 5000 bp, Protein Comparable to IEX and conventional CZE
|
Storage Conditions |
4°C
|
Technology |
Microfluidic Electrophoresis
|
Throughput |
DNA 28 sec
Protein 90 - 110 sec
RNA 80 sec
Small RNA 80 sec
|
Unit Size |
4 chips
|
Are you looking for resources, click on the resource type to explore further.
We are here to answer your questions.