Skip to main content
Menu
US

AlphaPlex 545 (Terbium) Anti-6His Acceptor Beads, 250 µg

AlphaPlex®-545 Acceptor beads conjugated to anti-6XHis antibody, for use in Alpha no-wash multiplexing assays.

This is a replacement for AP128TB.

For research use only. Not for use in diagnostic procedures. All products to be used in accordance with applicable laws and regulations including without limitation, consumption and disposal requirements under European REACH regulations (EC 1907/2006).

Feature Specification
Application Protein-Protein Interaction

AlphaPlex®-545 Acceptor beads conjugated to anti-6XHis antibody, for use in Alpha no-wash multiplexing assays.

This is a replacement for AP128TB.

For research use only. Not for use in diagnostic procedures. All products to be used in accordance with applicable laws and regulations including without limitation, consumption and disposal requirements under European REACH regulations (EC 1907/2006).

Product Variants
Unit Size: 250 µg
Part #:
AP178TB-C
List Price
USD 924.17
Unit Size: 5 mg
Part #:
AP178TB-M
List Price
USD 9,441.00
Unit Size: 25 mg
Part #:
AP178TB-R
List Price
USD 37,870.00

Overview

AlphaPlex®-545 Acceptor beads conjugated to anti-6XHis antibody. The mouse monoclonal antibody detects proteins containing accessible consecutive histidine residues at the amino or carboxy terminus. These beads can be used to capture His-tagged proteins and peptides, and can be used with Alpha Donor beads to create AlphaPlex no-wash assays for:

  • Protein-protein interaction assays
  • Protein detection assays
  • Enzymatic assays

AlphaPlex Acceptor beads are intended to be used in multiplexing assays, in conjunction with AlphaLISA Acceptor beads and Alpha Donor beads. In a typical Alpha assay:

  • 250 μg of Acceptor beads is sufficient to run 250-500 wells using a 50 μL reaction volume
  • 5 mg of Acceptor beads is sufficient to run 5,000-10,000 wells using a 50 μL reaction volume
  • 25 mg of Acceptor beads is sufficient to run 25,000-50,000 wells using a 50 μL reaction volume

Specifications

Application
Protein-Protein Interaction
Automation Compatible
Yes
Bead Type or Material
AlphaPlex Terbium (545) Acceptor
Brand
AlphaPlex
Conjugates
Anti-6X His
Detection Modality
Alpha
Product Group
Beads
Shipping Conditions
Shipped in Blue Ice
Target Class
Binding Assay
Technology
Alpha
Unit Size
250 µg

Video gallery

Resources

Are you looking for resources, click on the resource type to explore further.

1-1 of 1 Resources
Flyer Icon
Flyer
Measure more analytes in each well.

Now you can quantify multiple analytes in a single well for faster and more accurate results, even with low sample volumes

Scroll Icon