AlphaPlex™-545 (Terbium) Acceptor beads conjugated to antibody against human Histone H3 that is unmodified (H3K4), for use in Alpha no-wash multiplexing epigenetic assays.
For research use only. Not for use in diagnostic procedures. All products to be used in accordance with applicable laws and regulations including without limitation, consumption and disposal requirements under European REACH regulations (EC 1907/2006).
Feature | Specification |
---|---|
Application | Protein Quantification |
AlphaPlex™-545 (Terbium) Acceptor beads conjugated to antibody against human Histone H3 that is unmodified (H3K4), for use in Alpha no-wash multiplexing epigenetic assays.
For research use only. Not for use in diagnostic procedures. All products to be used in accordance with applicable laws and regulations including without limitation, consumption and disposal requirements under European REACH regulations (EC 1907/2006).
AlphaPlex-545 (Terbium) Acceptor beads conjugated to antibody against human Histone H3 that is unmodified (H3K4), for use in Alpha no-wash multiplexing epigenetic assays.
Alpha technology is a no-wash homogeneous proximity immunoassay that includes Alpha Donor and AlphaPlex-545 Acceptor beads to quantitate activity on histone, peptide, or protein substrates. In vitro modification of substrate is performed by incubating enzyme with appropriate cofactor and histone substrate. Following the enzymatic reaction, methylation or acetylation is monitored using specific antibody-conjugated AlphaPlex Acceptor beads. Following enzymatic reaction,streptavidin-coated Donor beads are added to capture the substrate, the beads are brought into close proximity in the absence of epigenetic mark on Histone H3 (Lysine 4) on the target substrate. The Donor beads are excited by a laser at 680 nm to release singlet oxygen. The singlet oxygen causes a reaction in the Acceptor bead and light emission is produced at 545 nm. This emission is proportional to the amount of unmodified / non-methylated / non-acetylated substrate present.
AlphaPlex-545 Acceptor beads are intended for use in multiplexing Alpha assays, in conjunction with Alpha Donor beads and AlphaLISA™ Acceptor beads.
Application |
Protein Quantification
|
---|---|
Automation Compatible |
Yes
|
Bead Type or Material |
AlphaPlex Terbium (545) Acceptor
|
Brand |
AlphaPlex
|
Conjugates |
Anti-H3K4
|
Detection Modality |
Alpha
|
Molecular Modification |
Unmodified
|
Product Group |
Beads
|
Shipping Conditions |
Shipped in Blue Ice
|
Target Class |
Epigenetics
|
Technology |
Alpha
|
Unit Size |
5 mg
|
Are you looking for resources, click on the resource type to explore further.
The AlphaPlex™ reagent system was designed to enable fast and easy transition from well-established AlphaLISA™ assays to...
Now you can quantify multiple analytes in a single well for faster and more accurate results, even with low sample volumes
We are here to answer your questions.