The AlphaLISA™ Human IL-28B Detection Kit is designed for detection and quantitation of human interleukin 28B in cell culture media or serum using a homogeneous (no-wash steps, no separation steps) assay.
For research use only. Not for use in diagnostic procedures. All products to be used in accordance with applicable laws and regulations including without limitation, consumption and disposal requirements under European REACH regulations (EC 1907/2006).
Feature | Specification |
---|---|
Application | Protein Quantification |
Dynamic Range | 1 - 100,000 pg/mL |
Limit of Detection | 16 pg/mL |
Limit of Quantification | 43 pg/mL |
Sample Volume | 5 µL |
The AlphaLISA™ Human IL-28B Detection Kit is designed for detection and quantitation of human interleukin 28B in cell culture media or serum using a homogeneous (no-wash steps, no separation steps) assay.
For research use only. Not for use in diagnostic procedures. All products to be used in accordance with applicable laws and regulations including without limitation, consumption and disposal requirements under European REACH regulations (EC 1907/2006).
Formats:
Features:
Interleukin 28B (IL28B), recently renamed interferon-λ 3 (IFNL3), is a cytokine encoded by the IL28 gene and is closely related to IL18A and IL29. IL28B plays a critical role in adaptive immune responses and regulates CD8+ T cell functions during vaccination. Clinically, it is involved in the protection from H1N1 viral infection and it can be used for predicting response to hepatitis C treatment with interferon and ribavirin. The present kit is designed to detect IL28B in human serum, plasma, and cell culture supernatants.
AlphaLISA technology allows the detection of molecules of interest in a no-wash, highly sensitive, quantitative assay. In an AlphaLISA assay, a biotinylated anti-analyte antibody binds to the Streptavidin-coated Donor beads while another anti-analyte antibody is conjugated to AlphaLISA Acceptor beads. In the presence of the analyte, the beads come into close proximity. The excitation of the Donor beads causes the release of singlet oxygen molecules that triggers a cascade of energy transfer in the Acceptor beads, resulting in a sharp peak of light emission at 615 nm.
Application |
Protein Quantification
|
---|---|
Automation Compatible |
Yes
|
Brand |
AlphaLISA
|
Detection Modality |
Alpha
|
Dynamic Range |
1 - 100,000 pg/mL
|
Limit of Detection |
16 pg/mL
|
Limit of Quantification |
43 pg/mL
|
Product Group |
Kit
|
Sample Volume |
5 µL
|
Shipping Conditions |
Shipped in Blue Ice
|
Target |
IL28B
|
Target Class |
Cytokines
|
Target Species |
Human
|
Technology |
Alpha
|
Therapeutic Area |
Inflammation
|
Unit Size |
5,000 Assay Points
|