The AlphaLISA™ immunoassay kit for human ANGPTL4 enables the quantitative determination of ANGPTL4 in serum, buffered solution, and cell culture supernatants using a homogeneous AlphaLISA assay (no wash steps).
For research use only. Not for use in diagnostic procedures. All products to be used in accordance with applicable laws and regulations including without limitation, consumption and disposal requirements under European REACH regulations (EC 1907/2006).
Feature | Specification |
---|---|
Application | Protein Quantification |
Dynamic Range | 25.77 - 3,000,000 pg/mL |
Limit of Detection | 25.77 pg/mL |
Limit of Quantification | 112.29 pg/mL |
Sample Volume | 5 µL |
The AlphaLISA™ immunoassay kit for human ANGPTL4 enables the quantitative determination of ANGPTL4 in serum, buffered solution, and cell culture supernatants using a homogeneous AlphaLISA assay (no wash steps).
For research use only. Not for use in diagnostic procedures. All products to be used in accordance with applicable laws and regulations including without limitation, consumption and disposal requirements under European REACH regulations (EC 1907/2006).
Formats:
Features:
Angiopoietin-like 4 (ANGPTL4), also known as HFARP, PGAR, or FIAF, is a 55 kDa glycoprotein that is structurally related to the angiopoietin family. It is secreted by the liver and fat tissue, and contains an N-terminal coiled-coil domain, and taC-terminal fibrinogen-like domain. Angiopoietin-like 4 plays a role in lipoprotein metabolism and angiogenesis. It is also involved in numerous cancers and is implicated in the metastatic process by modulating vascular permeability, cancer cell motility and invasiveness. This kit has been designed for the detection of Human Angiopoietin-like 4 in serum and cell culture supernatants.
AlphaLISA technology allows the detection of molecules of interest in a no-wash, highly sensitive, quantitative assay. In an AlphaLISA assay, a biotinylated anti-analyte antibody binds to the Streptavidin-coated Donor beads while another anti-analyte antibody is conjugated to AlphaLISA Acceptor beads. In the presence of the analyte, the beads come into close proximity. The excitation of the Donor beads causes the release of singlet oxygen molecules that triggers a cascade of energy transfer in the Acceptor beads, resulting in a sharp peak of light emission at 615 nm.
Application |
Protein Quantification
|
---|---|
Automation Compatible |
Yes
|
Brand |
AlphaLISA
|
Detection Modality |
Alpha
|
Dynamic Range |
25.77 - 3,000,000 pg/mL
|
Limit of Detection |
25.77 pg/mL
|
Limit of Quantification |
112.29 pg/mL
|
Product Group |
Kit
|
Sample Volume |
5 µL
|
Shipping Conditions |
Shipped in Blue Ice
|
Target |
ANGPTL4
|
Target Class |
Biomarkers
|
Target Species |
Human
|
Technology |
Alpha
|
Therapeutic Area |
Oncology
|
Unit Size |
500 Assay Points
|