AlphaLISA SureFire Ultra Human and Mouse Total BAD Detection Kit, 500 Assay Points

The AlphaLISA™ SureFire® Ultra™ Human and Mouse Total BAD assay is a sandwich immunoassay for quantitative detection of total BAD in cellular lysates using Alpha Technology.

For research use only. Not for use in diagnostic procedures. All products to be used in accordance with applicable laws and regulations including without limitation, consumption and disposal requirements under European REACH regulations (EC 1907/2006).

Feature Specification
Application Protein Quantification

The AlphaLISA™ SureFire® Ultra™ Human and Mouse Total BAD assay is a sandwich immunoassay for quantitative detection of total BAD in cellular lysates using Alpha Technology.

For research use only. Not for use in diagnostic procedures. All products to be used in accordance with applicable laws and regulations including without limitation, consumption and disposal requirements under European REACH regulations (EC 1907/2006).

Product Variants
Unit Size: 100 Assay Points
Part #:
ALSU-TBAD-A-HV
List Price
USD 694.00
Unit Size: 500 Assay Points
Part #:
ALSU-TBAD-A500
List Price
USD 2,346.00
Unit Size: 10,000 Assay Points
Part #:
ALSU-TBAD-A10K
List Price
USD 14,270.00
Unit Size: 50,000 Assay Points
Part #:
ALSU-TBAD-A50K
List Price
USD 46,060.00

Overview

Bcl-2-associated death promoter (BAD) is a pro-apoptotic member of the Bcl-2 family of proteins. BAD promotes apoptosis by binding to and neutralizing anti-apoptotic proteins such as Bcl-2 and Bcl-XL, thereby promoting cell death. The function of BAD is regulated through phosphorylation; when phosphorylated, it is sequestered in the cytoplasm, becomes inactive and binds to 14-3-3 proteins, preventing it from inducing apoptosis. Dysregulation of BAD can contribute to cancer progression due to impaired apoptosis.

The AlphaLISA SureFire Ultra Human and Mouse Total BAD Detection Kit is a sandwich immunoassay for the quantitative detection of total BAD in cellular lysates, using Alpha Technology.

Formats:

  • The HV (high volume) kit contains reagents to run 100 wells in 96-well format, using a 60 μL reaction volume.
  • The 500-point kit contains enough reagents to run 500 wells in 384-well format, using a 20 μL reaction volume.
  • The 10,000-point kit contains enough reagents to run 10,000 wells in 384-well format, using a 20 μL reaction volume.
  • The 50,000-point kit contains enough reagents to run 50,000 wells in 384-well format, using a 20 μL reaction volume.

 

AlphaLISA SureFire Ultra kits are compatible with:

  • Cell and tissue lysates
  • Antibody modulators
  • Biotherapeutic antibodies

 

Alpha SureFire Ultra kits can be used for:

  • Cellular kinase assays
  • Receptor activation studies
  • Screening

 

Specifications

Application
Protein Quantification
Automation Compatible
Yes
Brand
AlphaLISA SureFire Ultra
Detection Modality
Alpha
Host Species
Human
Mouse
Molecular Modification
Total
Product Group
Kit
Shipping Conditions
Shipped in Blue Ice
Target
BAD
Target Class
Phosphoproteins
Target Species
Human
Technology
Alpha
Therapeutic Area
Oncology
Unit Size
500 Assay Points

How it works

Total-AlphaLISA SureFire Ultra assay principle

The Total-AlphaLISA SureFire Ultra assay measures the expression level of a protein target in a cell lysate.

The Total-AlphaLISA SureFire Ultra assay uses two antibodies which recognize two different distal epitopes on the targeted protein. AlphaLISA assays require two bead types: Acceptor and Donor beads. Acceptor beads are coated with a proprietary CaptSure™ agent to specifically immobilize the assay specific antibody, labeled with a CaptSure™ tag. Donor beads are coated with streptavidin to capture one of the detection antibodies, which is biotinylated. In the presence of targeted protein, the two antibodies bring the Donor and Acceptor beads in close proximity whereby the singlet oxygen transfers energy to excite the Acceptor bead, allowing the generation of a luminescent Alpha signal. The amount of light emission is directly proportional to the quantity of protein present in the sample.

Assay Principle Total AlphaLISA SureFire Ultra

 

Total-AlphaLISA SureFire Ultra two-plate assay protocol

The two-plate protocol involves culturing and treating the cells in a 96-well plate before lysis, then transferring lysates into a 384-well OptiPlate™ plate before the addition of Total-AlphaLISA SureFire Ultra detection reagents. This protocol permits the cells' viability and confluence to be monitored. In addition, lysates from a single well can be used to measure multiple targets.

2plates-assay-protocol-AlphaLISA-Surefire-Ultra.jpg
Total-AlphaLISA SureFire Ultra one-plate assay protocol

Detection of Total target protein with AlphaLISA SureFire Ultra reagents can be performed in a single plate used for culturing, treatment, and lysis. No washing steps are required. This HTS designed protocol allows for miniaturization while maintaining robust AlphaLISA SureFire Ultra quality.

1 plate assay protocol AlphaLISA Surefire Ultra

Assay validation

Validation of Phospho (Ser112)/total BAD in EGF treated cells

A431 cells were seeded in a 96-well plate (20,000 cells/well) in complete medium, and incubated overnight at 37°C, 5% CO2. The cells were starved for 2 hours and then treated with increasing concentrations of EGF for 15 minutes.

After treatment, the cells were lysed with 100 µL of Lysis Buffer for 10 minutes at RT with shaking (350 rpm). BAD Phospho (Ser112) and Total levels were evaluated using respective AlphaLISA SureFire Ultra assays. For the detection step, 10 µL of cell lysate (approximately 2,000 cells) was transferred into a 384-well white OptiPlate, followed by 5 µL of Acceptor mix and incubated for 1 hour at RT. Finally, 5 µL of Donor mix was then added to each well and incubated for 1 hour at RT in the dark. The plate was read on an EnVision XCite™ using standard AlphaLISA settings.

As expected, EGF triggered a dose-dependent increase in the levels of Phospho BAD (Ser112) while Total BAD levels remained unchanged.

Pharmacological Validation of Total BAD
Validation of BAD total in endogenous cellular models

U2OS cells were seeded in a 96-well plate (40,000 cells/well) in complete medium, and incubated overnight at 37°C, 5% CO2. The cells were treated for 2 hours with increasing concentrations of Staurosporine.

After treatment, the cells were washed with HBSS and lysed with 100 µL of Lysis Buffer for 10 minutes at RT with shaking (350 rpm). BAD Phospho (Ser112) and Total levels were evaluated using respective AlphaLISA SureFire Ultra assays. For the detection step, 10 µL of cell lysate (approximately 4,000 cells) was transferred into a 384-well white OptiPlate, followed by 5 µL of Acceptor mix and incubated for 1 hour at RT. Finally, 5 µL of Donor mix was then added to each well and incubated for 1 hour at RT in the dark. The plate was read on an EnVision XCite using standard AlphaLISA settings.

As expected, Staurosporine triggered a dose-dependent decrease in the levels of Phospho BAD (Ser112) while Total BAD levels remained unchanged.

Pharmacological Validation of BAD Total

A549 cells were seeded in a 96-well plate (40,000 cells/well) in complete medium, and incubated overnight at 37°C, 5% CO2. The cells were treated for 1 hour with increasing concentrations of Wortmannin.

After treatment, the cells were lysed with 100 µL of Lysis Buffer for 10 minutes at RT with shaking (350 rpm). BAD Phospho (Ser136) and Total levels were evaluated using respective AlphaLISA SureFire Ultra assays. For the detection step, 10 µL of cell lysate (approximately 4,000 cells) was transferred into a 384-well white OptiPlate, followed by 5 µL of Acceptor mix and incubated for 1 hour at RT. Finally, 5 µL of Donor mix was then added to each well and incubated for 1 hour at RT in the dark. The plate was read on an EnVision XCite using standard AlphaLISA settings.

As expected, Wortmannin triggered a dose-dependent decrease in the levels of Phospho BAD (Ser136) while Total BAD levels remained unchanged.

Validation of BAD Total in endogenous cellular models

Assay specificity/selectivity

Detection of BAD total levels in various cell lines

Cells were seeded at 40,000 cells/well in a 96-well culture plate in complete medium and incubated overnight at 37°C, 5% CO2. Cells were lysed with 100 µL of Lysis Buffer.

Suspension cells were seeded at 100,000 cells/well (200 µL/well) in a 96-well culture plate in HBSS + 0.1% BSA and lysed with 50 µL 5X Lysis Buffer.

BAD Total levels were evaluated using the AlphaLISA SureFire Ultra assay. For the detection step, 10 µL of cell lysate were transferred into a 384-well white OptiPlate, followed by 5 µL of Acceptor Mix and incubated for 1 hour at RT. Finally, 5 µL of Donor Mix was then added to each well and incubated for 1 hour at RT in the dark. The plate was read on an EnVision XCite using standard AlphaLISA settings.

Detection of BAD Total levels in various cell lines

Resources